Database updated: 27 October 2026

Safety Information

Medsafe Online Recall Database

Detail of Recall

Type of Product:Medicine
Medsafe Reference:36555
Brand Name:Dianeal PD4 with 2.5% w/v glucose monohydrate
Dose Form/Strength:Dialysis solution .
Affected:
Recalling Organisation:Vantive Limited
7-9 Niall Burgess Road
Mt Wellington
Auckland 1060
Contact Information:
Manufacturer:Baxter Healthcare Pty Ltd
Brand Name:Extraneal
Dose Form/Strength:Dialysis solution 7.5% w/v
Affected:
Recalling Organisation:Vantive Limited
7-9 Niall Burgess Road
Mt Wellington
Auckland 1060
Contact Information:
Manufacturer:Baxter Healthcare SA Singapore Branch
Issue:Vantive is issuing a Product Alert for Dianeal PD4 and Extraneal CAPD solution bags for batches manufactured prior to 1 February 2026. In rare occurrences, the bags may have been misassembled during production and the solution line may be connected to the drain bag while the drain line may be connected to the solution bag.
Recall action type:Communication to healthcare professionals
Recall action:Product alert
Level of recall:Hospital/Pharmacy/Laboratory
Date Commenced:15/7/2026